Technical Specification:
|
|
|
|
INPUT / OUTPUT SPECIFICATIONS
|
|
|
a) Mic Inputs
|
|
|
|
General
|
|
|
|
Input configuration
|
Transformer Balanced
|
|
|
Input Impedance
|
200 Ohm
|
|
|
Sensitivity Level Range
|
Adjustable from –70 ÷-40 dBu (Trimmer adj.)
|
|
Input Level Range
|
±12 dBu
|
|
|
Maximum Input Level
|
- 30 dBu
|
|
|
Phantom Supply
|
48 Vdc selectable, with 3k3 c.c. protection
|
|
Insert section:
|
|
|
|
Insert Output configuration
|
Unbalanced
|
|
|
Insert Output impedance
|
100 Ohm
|
|
|
Insert Output level
|
0 dBu
|
|
|
Insert Input configuration
|
Unbalanced
|
|
|
Insert Input impedance
|
10 KOhm
|
|
|
Insert Input level
|
0 dBu
|
|
|
DJ Controls:
|
|
|
|
external DJ Slider control
|
Available
|
|
|
DJ Talk back
|
Available
|
|
|
In Start / Stop /Cough control
|
Available
|
|
|
Out Start / Stop Control
|
Available
|
|
|
Connector
|
D-Sub 15 Pole Female
|
|
|
b) Line Inputs
|
|
|
|
General
|
|
|
|
Input configuration
|
Electronically balanced
|
|
|
Input Impedance
|
10 K Ohm (600 Ohm wired selectable)
|
|
Input Level Range
|
±12 dBu
|
|
|
Headroom
|
+ 18 dBu
|
|
|
Connector
|
D-Sub 15 pole female
|
|
|
Digital Controls:
|
|
|
|
In Start / Stop
|
Available
|
|
|
Out Start / Stop Control
|
Available
|
|
|
c) Telephone Hybrid Module
|
|
|
|
General
|
|
|
|
Input configuration
|
Opto-coupled
|
|
|
Input impedance
|
600 Ohm Bal
|
|
|
Line Compensation
|
Automatically (max 5 Km)
|
|
|
Echo canceller
|
Digital (optional)
|
|
|
Tx Level
|
0
|
|
|
Rx Level Range
|
±12 dBu
|
|
|
Frequency response
|
300 Hz ÷ 3400 Hz (-2 dB) without Echocanc
|
|
|
300 Hz ÷ 3400 Hz (-1.5 dB) with Echocanc
|
|
Distortion
|
< 1.5 %
|
|
|
Noise
|
-60 dB.
|
|
|
Cross-talk
|
Digitally cancelled
|
|
|
Digital Controls:
|
|
|
|
In Start / Stop
|
Available
|
|
|
Out Start / Stop
|
Available
|
|
|
In Lock/ Meeting
|
Available
|
|
|
Out Call / Lock
|
Available
|
|
|
EXTERNAL INPUT
|
|
|
|
Input configuration
|
Electronically balanced
|
|
|
Input Impedance
|
10 K Ohm(600 Ohm wired selectable)
|
|
Input Level Range
|
±12 dBu
|
|
|
Headroom
|
+ 18 dBu
|
|
|
Connector
|
D-Sub 9 pole female
|
|
|
ANALOGUE OUTPUTS
|
|
|
|
Output configuration
|
Electronically balanced
|
|
|
Output Impedance
|
100 Ohm
|
|
|
PGM Output Level Range
|
-2 ÷ +13 dBu
|
|
|
Connector
|
D-Sub 9 pole female
|
|
|
UTL Output Level Range
|
-2 ÷ +13 dBu
|
|
|
Connector
|
D-Sub 9 pole female
|
|
|
AUX Output Level Range
|
-2 ÷ +13 dBu
|
|
|
Connector
|
D-Sub 9 pole female
|
|
|
C Room Mut.Output Level
|
+12 ÷ -12 dBu
|
|
|
Connector
|
D-Sub 9 pole female
|
|
|
C Room Mut.Output Level
|
+12 ÷ -12 dBu
|
|
|
Connector
|
D-Sub 9 pole female
|
|
|
HEAD PHONES (C.Room no Muted):
|
|
|
Configuration Type
|
Stereo unbalanced
|
|
|
Output Impedance
|
50 Ohm
|
|
|
Connector
|
JACK 6 mm
|
|
|
LOGIC INPUT
|
|
|
|
Configuration
|
Opto-coupled (with internally 330 Ohm protection)
|
|
Typical Voltage input
|
5 Vdc (for 10 mA input)
|
|
|
Max Reverse Voltage
|
5 Vdc
|
|
|
Connector
|
D-Sub 15 pole female
|
|
|
LOGIC OUTPUT
|
|
|
|
Configuration
|
Optic solid state relay
|
|
|
Max Voltage
|
50 Vdc/ac
|
|
|
Max Current
|
100 mA
|
|
|
Connector
|
D-Sub 15 pole female
|
|
|
GENERAL SPECIFICATIONS
|
|
|
|
FREQUENCY RESPONSE
|
|
|
|
Microphone Input
|
20 Hz ÷ 20 KHz ±1 dB (50 Hz ÷ 20 KHz ± 0.3 dB)
|
|
to program output
|
|
|
|
Line Input
|
30 Hz ÷ 20 KHz ±0.3 dB (20 Hz ÷ 20 KHz ± 1 dB)
|
|
to program output
|
|
|
|
NOISE
|
|
|
|
Micro Amplifier
|
-130 dBu RMS equivalent input noise, 200 ohm source, 20KHz Bandwidth
|
|
Line Amplifier
|
-120 dBu RMS equivalent input noise, 600 ohm source, 20KHz Bandwidth
|
|
Output Noise with one Microphone channel ON, Fader at 0 dB, input sensitivity at –40 dB, 200 ohm source:
|
better than
|
-84 dB (Wide 10 Hz / 23 KHz)
|
|
-72 dB (CCIR Wght)
|
|
Output Noise with: one Line channel ON, Fader at 0 dB, input sensitivity at 0 dB
|
better than
|
-86 dB (Wide 10 Hz / 23 KHz)
|
|
-75 dB (CCIR Wght)
|
|
Output Noise with:
|
better than
|
-89 dB (Wide 10 Hz / 23 KHz)
|
|
all input channel OFF
|
-78 dB (CCIR Wght)
|
|
DISTORTION T.H.D.
|
|
|
|
Microphone Input to program output
|
0.02%
|
|
|
Line Input to program output
|
0.01%
|
|
|
ASSIGN ISOLATION
|
|
|
|
1 KHz
|
better than -86 dB
|
|
|
20 KHz
|
better than -85 dB
|
|
|
CROSSTALK L/R
|
|
|
|
1 KHz
|
better than -78 dB
|
|
|
20 KHz
|
better than -66 dB
|
|
|
CROSSTALK PGM/ Other OUT
|
better than -76 dB
|
|
|
CMRR ( Line Input )
|
|
|
|
60 Hz
|
-56 dB
|
|
|
1 KHz
|
-56 dB
|
|
|
20 KHz
|
-56 dB
|
|
|
GENERAL DATA
|
|
|
|
Power Supply
|
115 / 230 VAC 50 – 60 Hz
|
|
|
Power Requirement
|
25 VA
|
|
|
Operating Temperature
|
0 ÷ 50 °C
|
|